Picture

Eagle Eye Anesthesia

  • Home
  • About
  • Products
    • Accessories
    • Monitors by Masimo
    • Monitors by VetTrends
    • New Anesthesia Machines
    • Oxygen Concentrators
    • Parts
    • Rebuilt Anesthesia Machines
    • Vaporizers
  • Services
    • Service & Repair
    • Rebuild, Customize or Upgrade
  • Additional Info
    • FAQs
    • Testimonials
    • Information Sheets
  • Contact
  • Our Team
  • Home
  • About
  • Products
    • Accessories
    • Monitors by Masimo
    • Monitors by VetTrends
    • New Anesthesia Machines
    • Oxygen Concentrators
    • Parts
    • Rebuilt Anesthesia Machines
    • Vaporizers
  • Services
    • Service & Repair
    • Rebuild, Customize or Upgrade
  • Additional Info
    • FAQs
    • Testimonials
    • Information Sheets
  • Contact
  • Our Team

Parts

Parts
(please call us at 904-739-4721 or email us at eagleyeanest@gmail.com for price and availability on all parts)
​

PictureClick For Larger Photo
Part number:  F-air canister , F-air canister bracket

F-air canister and canister bracket.  Used as a passive scavenge system, weigh canister before changing and re-weigh to determine if it needs to be changed.  Canister bracket mounts to wall or pole.

PictureClick For Larger Photo
Part number:  Manometer

Manometer used to measure and indicate pressure in centimeters of water on anesthesia machine.

PictureClick For Larger Photo
Part Number:  Flow meter knob and needle valve assembly

​
Flow meter needle valve assembly.  The constant turning off and on of this knob may cause the knob and/or needle valve to wear down and not function properly.  We stock both the knob (only) and the knob and needle valve assembly (pictured).  



PictureClick For Larger Photo
Part number:  Common gas outlet assembly

Common gas outlet assembly needed to allow for a non-rebreathing circuit to be used with the machine.

PictureClick For Larger Photo
Part numbers:  Breathing Circuit

Breathing circuit.  We stock single limb, double limb, adult and pediatric circuits ranging from 36 inches to 60 inches in length; with varying bags sizes from 1 liter to 3 liter. 

PictureClick For Larger Photo
Part numbers:  Bain Circuit

Bain Circuit is used with a Bain Block for a non-rebreather system.  Bain circuit is recommended to be used for patients less than 20 lbs.  Bain Circuit is 72 inches in length, bag size is 2 Liter.

PictureClick For Larger Photo
Part numbers:  Oxygen Hose

Oxygen hose 1/4" inside diameter.  Fits most applications for E-tank, H-tank and oxygen concentrators.  We will cut hose to size needed and crimp needed fittings (below), connectors (below) and manifolds/splitters (below) on hose ends.  

PictureClick For Larger Photo
Part numbers:  Hose Fittings

 We stock numerous fittings that are designed to be crimped or used with various hoses that adapt to most applications in the veterinary industry.

PictureClick For Larger Photo
Part numbers:  Oxygen Manifold with 2 Male Diss w/ Demand Check Valve Outlets & one Female Diss for inlet

Manifold available in 180 degree (left) and 90 degree (right).  Oxygen splitter to supply oxygen from any  two oxygen sources.  Often used in conjunction with oxygen concentrator and E-Tank or H-Tank sources.

PictureClick For Larger Photo
Part numbers:  Oxygen Manifold with 2 Male Diss w/ One Way Check Valve Outlets & one Female Diss for inlet

Oxygen manifold/splitter supplies oxygen from any two sources, such as an oxygen concentrator and an E-Tank or H-Tank.  One way check valves ensure proper flow "one way", flow is away from the source and to the anesthesia machine.  Manifold available in 180 degree (left) and 90 degree (right).  



PictureClick For Larger Photo
Part numbers:  Oxygen Regulator Adjustable

Oxygen Regulator Adjustable.  Adjustable flow control oxygen therapy.  Used to regulate oxygen flow from source to anesthesia machine.  

PictureClick For Larger Photo
Part numbers:  Oxygen Regulator Preset

Oxygen Regulator Preset.  Flow control is preset at 50 PSI for oxygen therapy.  Used to regulate oxygen flow from source to anesthesia machine.  

PictureClick For Larger Photo
Part numbers:  Flow Meter

Flow Meter.  Regulates flow of oxygen from machine to patient.  Measures flow in liters per minute.  

PictureClick For Larger Photo
Part numbers:  Replacement Wheels 

Replacement Wheels.  Universal replacement wheels for most pole mounted mobile anesthesia machines.  Prevents wheel lock up that could lead to serious damage of your machine if it were to fall over.        

PictureClick For Larger Photo
Part numbers:  Surgical Tubing/Hose

Surgical tubing/hose.  Used to connect vaporizer adapters to flow meter and absorber.  Used to connect common gas outlet and oxygen flush to the absorber.    

PictureClick For Larger Photo
Part numbers:  Breathing Bags

Breathing Bags.  We stock 500 cc, 1 Liter, 2 Liter, 3 Liter, 4 Liter and 5 Liter breathing bags.  Our bags (pictured) are of the highest quality and will last longer than most bags often found in veterinary clinics and hospitals.      

PictureClick For Larger Photo
Part numbers:  Eagle Eye Anesthesia Heavy Duty Non-Rebreather Circuit

Heavy Duty Non-Rebreather.  Built to last.  Will allow procedures to be performed on smaller patients using the common gas outlet to bypass the check valves and absorber on an anesthesia machine.  Oxygen flows through the vaporizer and directly into the patient with this set up.    

PictureClick For Larger Photo
Part numbers:  Oxygen Quick Connects 



Oxygen quick connects.  We have all of your oxygen quick connect needs.  Colder plastic and metal quick connects have been the industry standard in order to make your anesthesia machines easy to move or replace if the need arises.   

PictureClick For Larger Photo
Part numbers:  Popoff/Safety Valve

Popoff/Safety Valve.  One of the most important parts on your anesthesia machine.  We carry different types to fit most machines in the veterinary field.  The Popoff/Safety Valve is used to protect the patient from high airways pressure.  We have new and rebuilt Popoff/Safety valves in stock for various applications.    

PictureClick For Larger Photo
Part numbers:  Check Valve Discs

Check Valve Discs.  Check valve discs for numerous types of anesthesia machines.  Call us to replace your check valve discs.  We carry check valves for most makes and models of anesthesia machines.   

PictureClick For Larger Photo
Part numbers:  Check Valve Domes

Check Valve Domes.  We have new and used check valve domes.  Eagle Eye Anesthesia has a large inventory of used check valve domes that are like new for most machines in the veterinary field.     

PictureClick For Larger Photo
Part numbers:  Oxygen Wrench (metal) with Chain

Oxygen wrench (metal) with chain.  Turn your Oxygen E-Tank on and off with the wrench and attach it to your machine with the chain.     

PictureClick For Larger Photo
Part numbers:  Oxygen  Connectors 

Oxygen Connectors.  Make your machine more accessible with our wide variety of oxygen line connectors.  We can help you with all of your oxygen line needs from your walls or ceiling to the machine and everything in between.     

PictureClick For Larger Photo
Part numbers:  O-rings

O-rings.  We stock over 30 different sizes of O-rings to fit your anesthesia machine.  Most anesthesia machines and vaporizers have several different size o-rings on them in order to prevent leaks. 

PictureClick For Larger Photo
Part numbers:  Scavenge Hose, F-Air, Popoff Adapters

Scavenge Hose, F-Air and Popoff Adapters.  There are several sizes of scavenge hose as well as several sizes of scavenge systems/apparatus in the veterinary field.  We provide adapters to connect hose from your machine to the scavenging system.  We also, have adapters to fit most F-Air cans and Popoff valves.  Whether you need to add an F-Air can, reduce or enlarge your scavenge system hose or add an Occlusion Valve to your Popoff Valve, we have the adapter for you.  

PictureClick For Larger Photo
Part numbers:  Oxygen Regulator Mobile

Oxygen Regulator.  Need to use an E-tank in the field, literally, use this regulator to regulate the flow of oxygen from an E-tank anywhere you can carry the E-tank.  Great for zoos and large research facilities.  

PictureClick For Larger Photo
Part numbers:  Soda-Sorb Canisters

Soda-Sorb Canisters.  We have several different Soda-Sorb Canisters in our inventory.    

PictureClick For Larger Photo
Part numbers:  Vaporizer Inlet and Outlet Adapters

Vaporizer Adapters.  Used to adapt the inlet and outlet on a vaporizer to the type of hose being used for oxygen and anesthetic gas .  We have plastic and metal vaporizer adapters in stock.      

PictureClick For Larger Photo
Part numbers:  Vaporizer Manifolds

Vaporizer Manifolds.  We manufacturer our own Vaporizer Manifolds and have numerous types of refurbished Vaporizer Manifolds to choose from.    

PictureClick For Larger Photo
Part numbers:  Vaporizer Parts

Vaporizer Parts.  We have vaporizer parts to rebuild several vaporizer types, namely, Tec 3, Tec 4, Tec 5, Ohio and Drager vaporizers.      

PictureClick For Larger Photo
Part numbers:  Key Fill and Anti-Spill Adapters

Key Fill and Anti-Spill Adapters for vaporizers.  Isoflurane and Sevoflurane key fill and anti-spill adapters for your bottles of anesthetic.  Key fill adapters are a must for most applications.  Anti-Spill adapters prevent loss and keep everyone safe from spillage.        


    Quick Contact Form

Submit
Picture

Call Us At 904-739-4721

Picture

Servicing the Eastern United States


Picture

Contact Us


Picture
11233 St. Johns Industrial Pkwy
Suite 1,  Jacksonville, FL 32246

Picture
Email Us 

Picture
English - 800-760-6976

Picture
Espanol - 904-707-4197​